E308/9 Analogue Amplifier With Digital Display / Panel Meter

LVDT amplifier
Strain gauge transducer amplifier
Digital display module
Voltage / 4-20mA output
Limit trips
Simple trimpot controls


   Data sheet (119kb)
Signal conditioning is required where the output of a transducer needs to be boosted or changed into a form suitable for the monitor or logging device which will be used. Our digital display units have a built-in monitor device in the form of the digital display as well as analogue output.

Both E308 and E309 have high and low limits with voltage-free relay outputs. The E308 has a shunt calibration facility to enable calibration checks to be made.

A very wide range of gain adjustment ensures that our amplifiers are compatible with the vast majority of LVDT and strain gauge sensors available from any manufacturer.

Although they have a digital display, these units are entirely analogue and are configured using switches and potentiometers, there is no set-up software to learn.

Specification    E308 technical manual (209kb)    E309 technical manual (190kb)
Type E308 E309
Ac supply version 240Vac/120Vac (+5/-20%), 50/60Hz 10VA 240Vac/120Vac (+10/-20%), 50/60Hz 10VA
Compatible with Most full bridge strain gauge transducers
Most amplified transducers from any manufacturer
Any standard RDP LVDT.
Most LVDTs from any manufacturer.
Number of digits 4 ½, red LED (11mm) 4 ½, red LED (11mm)
Display update rate 2.5Hz 2.5Hz
Transducer excitation 1.2V to 15V & -15V, 60mA 5V, 5kHz (1kHz to 10kHz with component change), 100mA
Signal input range 5mV to 90V 50mV to 20V
Output details ±10V / 4-20mA (loop resistance 0 Ohms to 500 Ohms) ±10V / 4-20mA (loop resistance 0 Ohms to 500 Ohms)
Electrical output bandwidth 0 to 150Hz (3Hz with filter turned on) 0 to 300Hz
Input impedance 2M Ohms 100k Ohms
Linearity error ±0.02% F.S. typical ±0.1% F.S.
Output ripple (peak-to-peak) 10mV typical / 30uA typical 5mV typical / 10uA typical
Temperature coefficient (zero) ±0.01% F.S. /°C (typical) ±0.01% F.S. /°C (typical)
Temperature coefficient (span) ±0.01% F.S. /°C (typical) ±0.01% F.S. /°C (typical)
Limit trips Number of channels 2 2
Operation time 5ms 5ms
Contact rating 24Vdc (1A) / 120Vac (0.3A) 24Vdc (1A) / 120Vac (0.3A)
Operating temperature range 0°C to 50°C 0°C to 55°C
Total weight 1.3kg 1.3kg

PMHW 139mm
PMHH 67mm
PMBW 144mm
PMBH 72mm
PMD 185mm
PMDC 245mm
Panel cut-out 139mm X 67mm

All dimensions and specifications are nominal.www.rdpe.com/ex/e30x.htm20060906
Due to our policy of on-going development, specifications may change without notice. Any modification may affect some or all of the specifications for our equipment.
 
USA & Canada
RDP Electrosense
2216 Pottstown Pike
Pottstown, PA 19465
USA
Tel: 610-469-0850
Tel: 800-334-5838
Fax: 610-469-0852
Email: info@rdpe.com
Rest of the world
RDP Electronics Ltd
Grove Street, Heath Town
Wolverhampton, West Midlands, WV10 0PY
United Kingdom

Tel: +44 1902 457512
Fax: +44 1902 452000
Email: sales@rdpe.com